Kytola Oval Gear Flow Meter Model 2951
The Model 2951 oval gear flow meter by Kytola consists of two elliptical gears and a coil sensor or inductive proximity sensor, which measures the flow and sends a pulse to connected indicators, counters or automation systems. The Model 2951 can support a large viscosity range (30 – 1000 cSt) and several flow ranges, making it ideal for lubricant monitoring, industrial flow monitoring and process control.
Contact our team on +44(0)1825 764737 to place an order.
For a full overview of the technical specifications please click here.
Technical Spec
2951-1- | 2951-2- | 2951-5- | 2951-10- | 2951-20- | 2951-30- | 2951-60- | 2951-100- | |
---|---|---|---|---|---|---|---|---|
Output (pulses/l) | 820 | 1062 | 290 | 126.8 | 75.8 | 49.8 | 22.4 | 12.4 |
Viscosity range | 30 – 1000 cSt | |||||||
Body / cover material | Aluminium / Polyamide / AISI 316 | |||||||
Sensor | Namur; DIN 19234 (other types of sensor available as special construction) | |||||||
Seals | Viton® | |||||||
Gears | Composite polymer or brass | |||||||
Connection | ¼” | ¼” | ¼” | ¾” | ¾” | ¾” | 1″ | 1 ½” |
Weight | 265g | 255g | 280g | 1.1kg | 1.1kg | 1.5kg | 3.4kg | 12kg |
Max. pressure | 10 bar | |||||||
Max. temperature | +80°C | |||||||
Accuracy | ±5% of reading |